FS-9542 [avmd]: multithreaded

Now avmd detection is done in detector threads
processing audio frames with different resolution
and/or offsets. Detection decision is based on relative
standard deviation which dynamically adjusts to the signal.
Detection of amplitude, frequency and both simultaneously
is enabled and corresponding setting added to the configuration.
Frequency estimates are filtered with median filter.

This commit also resolves:
FS-9539 - Get estimates with different resolution
FS-9513 - Use adjustable thresholds
FS-9502 - Add detection mode setting
FS-9501 - Enable three modes of detection
FS-9407 - Add check of amplitude for NaN before appending to SMA buffer
FS-9139 - Unit test framework
This commit is contained in:
Piotr Gregor committed 2016-09-26 10:48:44 +01:00
1 parent 2b1f0da5c4
commit 8e189ed233
11 files changed
+1977 -698

No files matched your search

+9 -2
View File
@@ -37,13 +37,16 @@
<!-- required number of consecutive elements in the SMA buffer
without reset. This parameter helps to avoid false beeps, bigger this value is
smaller the probability of getting false detection -->
<param name="sample_n_continuous_streak" value="15"/>
<param name="sample_n_continuous_streak" value="5"/>
<!-- define number of samples to skip starting from the beginning
of the frame and/or after reset has happened. This serves the purpose of skipping first few
estimations on each frame, as these estimations may be inaccurate. This parameter also helps
to give more robust detections when it's value is increased (up to scertain limit of about 60). -->
<param name="sample_n_to_skip" value="15"/>
<param name="sample_n_to_skip" value="0"/>
<param name="require_continuous_streak_amp" value="1"/>
<param name="sample_n_continuous_streak_amp" value="5"/>
<!-- define/undefine this to enable/disable simplified estimation
of frequency based on approximation of sin(x) with (x)
@@ -55,6 +58,10 @@
<!-- define/undefine to enable/disable avmd on external channel -->
<param name="outbound_channel" value="1"/>
<!-- determines the mode of detection, default is both amplitude and frequency -->
<param name="detection_mode" value="2"/>
<!-- Per call settings end -->
</settings>
</configuration>